Слайд 1ABB Welcome M
Commission & Application
June. 2013 CNDEX
© ABB Group
Слайд 2
Content
© ABB Group
Overview Main Devices
Commission & Wiring
General Ruler
of Installation
Application & Solution
Слайд 3Overview Main Devices
Outdoor Station
© ABB Group
Overview Main Devices
Commission &
Wiring
General Ruler
Application & solution
Outdoor Station
Indoor Station
Guard Unit
System Devices
Слайд 4Overview Main Devices
Indoor Station
© ABB Group
M2200.-.
Audio handset
M2230.-.
4.3” Video handset
M2231.-.
4.3”
Video hands-free
M2233.-.
7” Video hands-free
Overview Main Devices
Commission & Wiring
General Ruler
Application &
solution
Outdoor Station
Indoor Station
Guard Unit
System Devices
Слайд 5Overview Main Devices
Guard Unit
© ABB Group
M2303
Guard unit
Overview Main Devices
Commission
& Wiring
General Ruler
Application & solution
Outdoor Station
Indoor Station
Guard Unit
System Devices
Слайд 6Overview Main Devices
System Devices
© ABB Group
M2300
System controller,8U
M2301
Mini-system controller,4U
M2302
Gateway,4U
M2305
Switch actuator
83325/2-500
Outdoor
video distributor
M2304
Video distributor
Overview Main Devices
Commission & Wiring
General Ruler
Application & solution
Outdoor
Station
Indoor Station
Guard Unit
System Devices
Слайд 7
Content
© ABB Group
Overview Main Devices
Commission & Wiring
General Ruler
of Installation
Application & Solution
Слайд 8Commission & Wiring
Audio Module
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Release the lock (LOCK-GND)
(All locks except magnetic lock)
Local power supply for outdoor station
Camera module
Слайд 9Commission & Wiring
Audio Module
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
* Door lock release time 1-10s is available for the lock (LOCK-GND);
While for the lock connected with “NC-NO-COM”, the time is fixed as 3s, and it can be set by entering system setting by display module.
Слайд 10Commission & Wiring
Camera Module
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
CVBS: Composite Video Broadcast Signal
H ± 15°, V ± 15°
Option1:
Camera powers on all time
Option 2:
Camera only powers on when surveiling
Слайд 11Commission & Wiring
Other modules
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Слайд 12Commission & Wiring
Connect all modules together
© ABB Group
Main Devices
Commission
& Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video
Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Слайд 13Commission & Wiring
Audio Handset
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
*“Default OS: 1-9 ” can be set when entering system setting.
Details please see user manual.
Слайд 14Commission & Wiring
4.3” Video Handset
© ABB Group
Main Devices
Commission &
Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3”
Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Local power supply for indoor station
20-30VDC
Слайд 15Commission & Wiring
4.3” Video Hands-free
© ABB Group
E.g. Address of
indoor station:
Main Devices
Commission & Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other
Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Local power supply for indoor station
20-30VDC
Слайд 16Commission & Wiring
7” Video Hands-free
© ABB Group
Main Devices
Commission &
Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3”
Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
*The address of 7” video hands-free can be set from 001-250 when entering system setting.
Details please see user manual.
Слайд 17Commission & Wiring
Guard Unit
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Local power supply for guard unit
20-30VDC
Слайд 18Commission & Wiring
System Controller – M2300
© ABB Group
Main Devices
Commission
& Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video
Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Technical Data:
Input: 100~240V(AC)
Output current: 28V(DC), 1.2A
Dimension: 8U
Слайд 19Commission & Wiring
Min-system Controller – M2301
© ABB Group
Main Devices
Commission
& Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video
Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Gateway
Video Distributor
Switch Actuator
Technical Data:
Input: 100~240V(AC)
Output current: 28V(DC), 0.65 A
Dimension: 4U
Слайд 20Commission & Wiring
Distributor
© ABB Group
Main Devices
Commission & Wiring
General Ruler
Application
& solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7”
Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Слайд 21Commission & Wiring
Switch Actuator
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video
Hands-free
7” Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Working mode is defined as follows:
MODE=00 – Extend Door Bell Mode
MODE=01 – Door opening
MODE=10 – Time relay
MODE=11 – Toggle on/off
Details see user manual.
Слайд 22Commission & Wiring
Gateway
© ABB Group
Main Devices
Commission & Wiring
General Ruler
Application
& solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7”
Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Working mode is defined as follows:
MODE=000 – Building Gateway Mode
MODE=001 – Floor Gateway Mode
MODE=010 – Apartment Gateway Mode
MODE=011 – Auxiliary Power Supply Mode
MODE=100 – Line Amplifier Mode
Слайд 23Commission & Wiring
Gateway- Scenario 1 for buildings
© ABB Group
Configuration of Gateway:
MODE=000 – Building Gateway Mode
Address = Building No.
(<=60)
Main Devices
Commission & Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Слайд 24Commission & Wiring
Gateway- Scenario 2 for floor system
© ABB Group
Building 01
Configuration of Gateway:
MODE=001 – Floor Gateway Mode
Address = Minimum
address of indoor station within this floor. (<=99)
Eg. Address of the gateway of 2nd floor=05, is the starting address of first apartment of 2nd floor:05
Main Devices
Commission & Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Слайд 25© ABB Group
Commission & Wiring
Gateway – Scenario 3 for
apartment system
Building 01
Configuration of Gateway:
MODE=010 – Apartment Gateway Mode
Address =
Apartment No. (<=99) (Configured as a normal indoor station)
Main Devices
Commission & Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Слайд 26© ABB Group
Commission & Wiring
Gateway – Scenario 4 for
auxiliary power supply
Configuration of Gateway:
MODE=011 – Auxiliary power supply
mode
Address = 00
Outdoor station for building 01
Main Devices
Commission & Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Слайд 27© ABB Group
Commission & Wiring
Gateway – Scenario 5 for
double the distance
Configuration of Gateway:
MODE=100 – Line amplifier mode
Address
= 00
Main Devices
Commission & Wiring
General Ruler
Application & solution
Audio Module
Camera Module
Other Modules
Audio Handset
4.3” Video Handset
4.3” Video Hands-free
7” Video Hands-free
Guard Unit
System Controller
Video Distributor
Switch Actuator
Gateway
Слайд 28
Content
© ABB Group
Overview Main Devices
Commission & Wiring
General Ruler
of Installation
Application & Solution
Слайд 29General Ruler For Installation
Rulers for IS — M/S ON/OFF
© ABB
Group
Main Devices
Commission & Wiring
General Ruler
Application & solution
Rulers for IS
Rulers
for multi-buildings
Capacity
Distance
“M/S – ON” or “M/S – OFF” : (master / slave)
Only one indoor station in each apartment must be set as "Master" ('M/S on').
All additional indoor stations in the same apartment must be set as "Slave" ('M/S off').
Слайд 30General Ruler For Installation
Rulers for IS — RC ON/OFF (Audio
System)
© ABB Group
Looping Connection
Branch Line Connection
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Rulers for IS
Rulers for multi-buildings
Capacity
Distance
“RC-ON” or “RC-OFF”:
In pure audio installations, the terminal resistor must always be deactivated ‘RC OFF'.
Слайд 31© ABB Group
Rulers for IS — RC ON/OFF (Video
System)
General Ruler For Installation
Main Devices
Commission & Wiring
General Ruler
Application & solution
Rulers
for IS
Rulers for multi-buildings
Capacity
Distance
“RC-ON” or “RC-OFF”:
In video installations or mixed audio and video installations, the terminal resistor must be activated on the last device of the arm ‘RC ON'.
Looping Connection
Branch Line Connection
Слайд 32© ABB Group
Combined Connection
Rulers for IS — RC ON/OFF
(Audio & Video System)
General Ruler For Installation
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Rulers for IS
Rulers for multi-buildings
Capacity
Distance
Слайд 33General Ruler For Installation
Rulers for Multi-Buildings
© ABB Group
Looping Connection
Main
Devices
Commission & Wiring
General Ruler
Application & solution
Rulers for IS
Rulers for multi-buildings
Capacity
Distance
“RC-ON” or “RC-OFF”:
the terminal resistor must be activated on the last device of the arm ‘RC ON'.
Building 1
Building 2
Building n
Building 3
Слайд 34General Ruler For Installation
Rulers for Multi-Buildings
© ABB Group
Branch Line
Connection
Main Devices
Commission & Wiring
General Ruler
Application & solution
Rulers for IS
Rulers for
multi-buildings
Capacity
Distance
“RC-ON” or “RC-OFF”:
the terminal resistor must be activated on the last device of the arm ‘RC ON'.
Building 1
Building 2
Building 4
Building 3
Слайд 35General Ruler For Installation
Capacity
© ABB Group
Main Devices
Commission & Wiring
General
Ruler
Application & solution
Rulers for multi-IS
Rulers for multi-buildings
Capacity
Distance
9 outdoor stations
per building
The system may include:
60 buildings
250 indoor stations per building
9 guard units per building
50 video indoor stations per system controller *
100 audio indoor stations per system controller *
*Remark:
only to the application that one apartments with one indoor station.
Слайд 36© ABB Group
General Ruler For Installation
Insulated section:
When calculating capacity, all calculations must be based on each
insulated system that is only one system controller is included.
Sum of segment inside one insulated section must be less than 800m.
4 insulated sections are contained in the following example:
Слайд 37© ABB Group
General Ruler For Installation
Only Gateway can extend
the distance:
When calculating distance from outdoor station(gate
station) to the farthest indoor station, all calculations must be done separately if multi-gateways are involving in this communication channel
Distance need to be separated into 3 sections in following example.
Remark:
A maximum of 2 Gateways(building gateway/ apartment gateway/ floor gateway) + 2 Gateways(additional power supply mode) can be used in cascade.
( By gateways used in cascade, it means gateway crossed by an outdoor station to indoor station connection)
Слайд 38General Ruler For Installation
Capacity
© ABB Group
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Precondition:
*Unit: apartment
For example: 50 means 50apartments with 1 indoor station for each apartment;
15 means 15 apartments with 2 indoor stations for each apartment.
Слайд 39General Ruler For Installation
Capacity
© ABB Group
Precondition:
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 40General Ruler For Installation
Capacity
© ABB Group
Precondition:
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 41General Ruler For Installation
Capacity
© ABB Group
Precondition:
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 42General Ruler For Installation
Capacity
© ABB Group
Precondition:
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 43General Ruler For Installation
Capacity
© ABB Group
Precondition:
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 44General Ruler For Installation
Capacity
© ABB Group
Precondition:
For kit and small
building application:
*The table should be applied for each insulated system,
which is only one system controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 45General Ruler For Installation
Capacity
© ABB Group
Precondition:
*The table should be
applied for each insulated system, which is only one system
controller included.
*If system including several system controllers, using gateway to separate the system into several insulated systems.
*The data is only for reference, final data please refer to user manual!!!!!
Слайд 46© ABB Group
General Ruler For Installation
Capacity
For example:
In the realization
of the systems we must consider the possibility to insert
other components:
one video outdoor distributor = 1 indoor station
one guard unit = 20 indoor stations
Слайд 47General Ruler For Installation
Distance -- one building
© ABB Group
Looping
Connection
Слайд 48General Ruler For Installation
Distance -- one building
© ABB Group
Branch
Line Connection
Слайд 49© ABB Group
General Ruler For Installation
Distance – residential complexes
Looping
Connection
Слайд 50© ABB Group
General Ruler For Installation
Distance – residential complexes
Looping
Connection
Слайд 51© ABB Group
General Ruler For Installation
Distance – residential complexes
Looping
Connection
Слайд 52General Ruler For Installation
Distance – residential complexes
© ABB Group
Branch
Line Connection
Слайд 53© ABB Group
Distance – residential complexes
Branch Line Connection
General Ruler
For Installation
Слайд 54© ABB Group
Distance – residential complexes
Branch Line Connection
General Ruler
For Installation
Слайд 55
Content
© ABB Group
Overview Main Devices
Commission & Wiring
General Ruler
of Installation
Application & Solution
Слайд 56Application and solution
© ABB Group
1. Planning
2. Installation & Wiring
3.
Commission
According to user case :
Choose correct devices ( modules
of outdoor station; Indoor stations; system controller; the system devices which are needed.)
Calculate the system consumption units, distances
Planning the connection (Loop connection; Branch line connection)
Install devices after reading user manuals
Using the prepared wire to wiring the devices together
Configure each device correctly
DONE!
Main Devices
Commission & Wiring
General Ruler
Application & solution
Слайд 57Application and solution
Single-family house, audio/video
© ABB Group
2-wire bus line
Main
Devices
Commission & Wiring
General Ruler
Application & solution
Single-family house, audio/video
Слайд 58Application and solution
Single-family house, audio/video
© ABB Group June 11, 2013
| Slide ‹#›
Main Devices
Commission & Wiring
General Ruler
Application & solution
Single-family house,
audio/video
Слайд 59Application and solution
Multi-family house, audio
© ABB Group
M Range
Product Overview
Main
Features
Main Functions
Topology and solution
Multi-family house, audio
2-wire bus line
Слайд 60Application and solution
Multi-family house, audio
© ABB Group June 11, 2013
| Slide ‹#›
Remark:
Up to 250 audio handsets.
All consumer units required
must be covered by the System Controller.
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Multi-family house, audio
Слайд 61Application and solution
Multi-family house, audio/video
© ABB Group
M Range
Product Overview
Main
Features
Main Functions
Topology and solution
Multi-family house, audio/video
2-wire bus line
Слайд 62Application and solution
Multi-family house, audio/video
© ABB Group
Remark:
Up to 250
audio & video Indoor Stations.
All consumer units required must be
covered by the System Controller.
100~240V~
M2300
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Multi-family house, audio/video
Слайд 63Application and solution
Multi-indoor stations per apartment, using auxiliary power supply
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
One
family with multi-indoor station
2-wire bus line
Слайд 64Application and solution
© ABB Group
100~240V~
M2300
M Range
Product Overview
Main Features
Main Functions
Topology
and solution
One family with multi-indoor station
0
0
100-240V~
M2300
Multi-indoor stations per apartment, using
auxiliary power supply
Слайд 65Application and solution
Additional power supply for 2nd-indoor station
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
One family with multi-indoor
station
2-wire bus line
Слайд 66Application and solution
One family with multi-indoor station
© ABB Group
100~240V~
100~240V~
M2301
M2300
M
Range
Product Overview
Main Features
Main Functions
Topology and solution
One family with multi-indoor station
Слайд 67Application and solution
Commercial object, audio/video
© ABB Group
M Range
Product Overview
Main
Features
Main Functions
Topology and solution
Commercial object, audio/video
2-wire bus line
Слайд 68Application and solution
Commercial object, audio/video
© ABB Group
Remark:
Up to 9
Outdoor Stations
All consumer units required must be covered by the
System Controller.
100~240V~
M2300
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Commercial object, audio/video
Слайд 69Application and solution
Guard unit application
© ABB Group
M Range
Product
Overview
Main Features
Main Functions
Topology and solution
Guard unit application
2-wire bus line
Слайд 70Application and solution
Guard unit application
© ABB Group
100~240V~
100~240V~
Remark:
Up to
9 Guard for the building, and only one Master is
allowed.
All consumer units required must be covered by the System Controller.
M2301
M2300
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Guard unit application
Слайд 71Application and solution
Apartment system, with 2nd-confirmed outdoor station
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Apartment system, with 2nd-confirmed
outdoor station
2-wire bus line
Слайд 72Application and solution
Apartment system, with 2nd-confirmed outdoor station
© ABB Group
100~240V~
0
1
9
9
100~240V~
100~240V~
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Apartment system, with 2nd-confirmed
outdoor station
Слайд 73Application and solution
Floor system, with outdoor station connected for each
floor
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Floor
system, with outdoor station connected for each floor
2-wire bus line
Слайд 74Application and solution
Floor system, with outdoor station connected for each
floor
© ABB Group
Remark:
Up to 250 Indoor Stations.
100~240V~
0
1
9
9
100~240V~
100~240V~
M2300
M2301
M2301
M Range
Product Overview
Main
Features
Main Functions
Topology and solution
Floor system, with outdoor station connected for each floor
Слайд 75Application and solution
Auxiliary power supply for the bus
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Auxiliary power supply for
the bus
2-wire bus line
Слайд 76Application and solution
Auxiliary power supply for the bus
© ABB Group
Remark:
Up to 250 Indoor Stations.
100~240V~
0
0
0
0
100~240V~
100~240V~
M2301
M2301
M2300
M Range
Product Overview
Main Features
Main Functions
Topology and
solution
Auxiliary power supply for the bus
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
7” VIS
Слайд 77Application and solution
Residential complexes, with looping connection
© ABB Group
M
Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential complexes, with looping connection
2-wire
bus line
Слайд 78Application and solution
Residential complexes, with looping connection
© ABB Group
100~240V~
100~240V~
6
0
0
1
100~240V~
Remark:
All
consumer units required must be covered by the System Controller.
M2300
M2300
M2300
M
Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential complexes, with looping connection
Слайд 79Application and solution
Residential complexes, with branch line connection
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential complexes, with branch
line connection
2-wire bus line
Слайд 80Application and solution
Residential complexes, with branch line connection
© ABB Group
100~240V~
100~240V~
100~240V~
0
2
0
1
Remark:
All consumer units required must be covered by the System
Controller.
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential complexes, with branch line connection
Слайд 81Application and solution
Residential complexes with guard unit
© ABB Group
M
Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential complexes with guard unit
2-wire
bus line
Слайд 82Application and solution
Residential complexes with guard unit
© ABB Group
Gate
100~240V~
100~240V~
100~240V~
100~240V~
~
100~240V~
0
1
0
2
M
Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential complexes with guard unit
100~240V~
Слайд 83Application and solution
Group of villas
© ABB Group
M Range
Product Overview
Main
Features
Main Functions
Topology and solution
Group of villas
2-wire bus line
Слайд 84Application and solution
Group of villas
© ABB Group
Gate
100~240V~
100~240V~
9
9
0
1
100~240V~
M Range
Product Overview
Main
Features
Main Functions
Topology and solution
Group of villas
Слайд 85Application and solution
Residential complexes, with looping connection and long distances
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential
complexes, with looping connection and long distances
2-wire bus line
Слайд 86Application and solution
Residential complexes, with looping connection and long distances
© ABB Group
Gate
100~240V~
100~240V~
100~240V~
6
0
0
1
0
0
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential
complexes, with looping connection and long distances
Слайд 87Application and solution
Residential complexes, with branch line connection and long
distances
© ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential
complexes, with branch line connection and long distances
2-wire bus line
Слайд 88Application and solution
Residential complexes, with branch line connection and long
distances
© ABB Group
Gate
100~240V~
100~240V~
0
2
0
1
0
0
100~240V~
100~240V~
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Residential
complexes, with branch line connection and long distances
Слайд 89Application and solution
Application for more than 250 apartments per building
©
ABB Group
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Application for
more than 250 apartments per building
2-wire bus line
Слайд 90Application and solution
Application for more than 250 apartments per building
©
ABB Group
0
1
0
0
6
0
100-240V~
100-240V~
100-240V~
Gate
M Range
Product Overview
Main Features
Main Functions
Topology and solution
Application for
more than 250 apartments per building
Слайд 91Application and solution
Legend
© ABB Group
Product Overview
Main Features
Main Functions
Application &
Solution
Legend
Note
Main Entrance
Video Outdoor
System controller
Electronic door opener
7” Video Hands-free
4.3” Video Hands-free
4.3”
Video Handset
Audio Handset
4.3” Video Handset Guard
Mini System controller
Indoor Distributor
Outdoor Distributor
Gateway
CCTV
Light